NWAV™ X-Pol 16-Port Antenna
|
|
|
Frequency bands, MHz |
698-806 |
806-894 |
1695-1880 |
1850-1990 |
1920-2180 |
2300-2360 |
2496-2690 |
Polarization |
± 45° |
± 45° |
Average gain over all tilts, dBi |
12.7 |
13.0 |
15.9 |
16.2 |
16.8 |
16.8 |
16.6 |
Horizontal beamwidth (HBW), degrees1 |
46 |
43 |
40 |
40 |
36 |
31 |
29 |
Front-to-back ratio, co-polar power @180°± 30°, dB
|
>25.0 |
>25.0 |
>25.0 |
>25.0 |
>25.0 |
>25.0 |
>25.0 |
X-Pol discrimination (CPR) at boresight, dB
|
>20.0 |
>18.0 |
>19 |
>18 |
>18 |
>18 |
>18 |
Vertical beamwidth (VBW), degrees1 |
31.0 |
27.0 |
12.0 |
11.4 |
11.0 |
10.0 |
9.0 |
Electrical downtilt (EDT) range, degrees |
2-16 |
0-9 |
First upper side lobe (USLS) suppression, dB1 |
≤-18.0 |
≤-18.0 |
≤-18.0 |
≤-18.0 |
≤-18.0 |
≤-18.0 |
≤-18.0 |
Cross-polar isolation, port-to-port, dB1 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
Max VSWR / return loss, dB |
1.5:1 / -14.0 |
1.5:1 / -14.0 |
Max passive intermodulation (PIM), 2x20W carrier, dBc |
-153 |
-153 |
Max input power per any port, watts |
300 |
250 |
Total composite power all ports, watts
|
1500 |
1 Typical value over frequency and tilt - * For ports 13-16, the electrical downtilt is FET configured with internal RET, where the required electrical downtilt is defined at the time of order per the ordering information below.
Frequency bands, MHz |
3400-3550 |
3550-3700 |
3700-3980 |
Polarization |
± 45° |
Average gain over all tilts, dBi |
14.4 |
14.5 |
14.6 |
Horizontal beamwidth (HBW), degrees |
37 |
37 |
36 |
Front-to-back ratio, co-polar power @180°± 30°, dB
|
>25 |
>25 |
>25 |
Vertical beamwidth (VBW), degrees1 |
18.0 |
18.0 |
17.0 |
Electrical downtilt (EDT) range, degrees |
2-12 orderable in 1 deg increments |
First upper side lobe (USLS) suppression, dB1 |
≤-15 |
≤-15 |
≤-15 |
Cross-polar isolation, port-to-port, dB1 |
25 |
25 |
25 |
Max VSWR / return loss, dB |
1.5:1 / -14.0 |
Max input power per any port, watts |
150 |
Total composite power all ports (1-10), watts
|
1500 |
Antenna model
|
Description
|
MX16FRO445-xx (xx represents the FET in one degree increments for 3.4-3.8 GHz)
|
4F X- Pol 16 PORT FRO 45⁰ 2-16⁰/ 0-9⁰/2-12⁰, 4.3-10 & SBT
|
xx=02 thru 12 for each 1 degree tilt 3.4-3.8 GHz
Examples: MX16FIT465-02 – 2deg, MX16FIT465-09 – 9deg, MX16FIT465-12-12deg |
Optional accessories
|
AISG cables
|
M/F cables for AISG connections |
PCU-1000 RET controller
|
Stand-alone controller for RET control and configurations |
91900314-02
|
Dual Mount Bracket (see 91900314 bracket document for details)
|
Dimensions height/width/depth, inches (mm) |
56.9/ 20.0/ 8.0 (1445.3/ 508.0/ 203.2) |
Shipping dimensions length/width/height, inches (mm)
|
61.9/ 26/ 15 (1572.3/ 600/ 381) |
No. of RF input ports, connector type, and location |
16 x 4.3-10 female, bottom |
RF connector torque |
96 lbf·in (10.85 N·m or 8 lbf·ft) |
Net antenna weight, lb (kg) |
51.7 (23.5) |
Shipping weight, lb (kg)
|
84.7 (38.4) |
Antenna mounting and downtilt kit included with antenna
|
91900318 |
Net weight of the mounting and downtilt kit, lb (kg)
|
18 (8.2) |
Range of mechanical up/down tilt
|
-2° to 12° |
Rated wind survival speed, mph (km/h) |
150 (241) |
Frontal and lateral wind loading @ 150 km/h, lbf (N) |
102.1 (454.2), 47.3 (210.4) |
EPA frontal and lateral, ft2, (m2) |
4.6 (0.43), 2.1 (0.20) |
|
|
RET location
|
Integrated into antenna
|
RET interface connector type
|
8-pin AISG connector per IEC 60130-9
or RF port bias-t |
RET connector torque |
Min 0.5 N·m to max 1.0 N·m (hand pressure & finger tight) |
RET interface connector quantity
|
3 pairs of AISG male/female connectors and 3 RF port Bias Ts |
RET interface connector location
|
Bottom of the antenna
|
Total no. of internal RETs 698-894 MHz |
1 |
Total no. of internal RETs 1695-2690 MHz
|
2 |
Total no. of internal RETs 3400-3980 MHz
|
1 |
RET input operating voltage, vdc
|
10-30 |
RET max power consumption, idle state, W
|
≤ 2.0
|
RET max power consumption, normal operating conditions, W
|
≤ 13.0
|
RET communication protocol
|
AISG 2.0 / 3GPP
|
Each RET device can be controlled either via the designated external AISG connector or RF smart bias-t port as shown below: |
Band
|
RF port
|
1695-2690
|
5-8
|
3400-3980 |
13-16 |
|
|
Band
|
RF port
|
1695-2690 |
9-12 |
|
|
Note: The RET Device for 3400-3800 MHz is connected via the 1695-2690 Port 5 Bias T port or 1695-2690/3400-3800 MHz AISG ports. |
6 sets of radiating arrays
R1: 698-894 MHz
R2: 698-894 MHz
Y1: 1695-2690 MHz
Y2: 1695-2690 MHz
Y3: 1695-2690 MHz
Y4: 1695-2690 MHz
P1: 3400-3980 MHz
P2: 3400-3980 MHz
|
Band |
RF port
|
698-894
|
1-4
|
1695-2690
|
5-12
|
3400-3980 |
13-16
|
|
|
V2.0
12/12/23