UXP-NM-14S

N Male Connector for 1/4” Superflexible Cable

General Specification
Interface/gender N Male
Cables supported1 Manufacturer P/N Manufacturer P/N
  JMA Wireless JMA14S-50 Wireless Supply WS14/SF
JMA14SP-50 HUBER+SUHNER SUCOFEED 1/4 HFFR
Trilogy APC014J50 SUCOFEED 1/4 HF
CommScope FSJ1-50A RFS SCF14-50J
FSJ1RK-50B SCF14-50JFN
PTS1-50-P Eupen EC1- 50-HF
Hansen RF5014S Times SPP-250-LLPL
RF5014SZ Times SPO-250
Weight 0.128 lbs. | 58.1 g
JMA Weather Protection System WPS-4MT-14S
Tools required JMA part number Comment
Cable preparation SP-14S No coring required
Connector compression HCG-FRAMESET-14B, HCG-CC  
Torque wrench TW1412 14 lbf·in | 1.58 N·m
Frequency band VSWR Return loss (dB)
DC-1000 MHz 1.02 40
1000–2000 MHz 1.03 36
2000–4000 MHz 1.05 32
4000–6000 MHz 1.08 28
Electrical Specification Comment
Connector impedance 50 ohm  
Operating frequency band DC–6 GHz  
3rd order IMD dynamic, (PIM) -161 dBc, typical IEC 62037-2, -3
DC test voltage 1600 V  
Center contact resistance ≤ 1.0 milliohm  
Outer contact continuity 0.2 milliohm max.    
Average power 400 W @ 900 MHz  
Peak power, max. 6.4 kW  
Insertion loss, typical 0.05 dB Per connector
Shielding effectiveness < -120 dB @ 0-1 GHz
Mechanical Specification Comment
Pull force combined .67 kN | >150 lb Cable limited
Cable retention torque 2 N·m | 1.5 lbf·ft Cable limited
Interface durability 500 cycles IEC 61169-4:9.5
Environmental Specification Test
Operating temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Storage temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Accelerated UV 1000 hr ASTM G154
Immersion test method Mated & unmated, IP68 IEC 60529:2001 & ANSI/SCTE 60
Water jetting test method Mated & unmated, IP66 IEC 60529:2001
Mechanical shock test method Pass IEC 60068-2-27
Thermal shock test method Pass IEC 60068-2-14
Vibration test method 100 m/s2, 2 Hz to 200 Hz IEC 61169-1:2003
Corrosion test method 1000 hr IEC 60068-2-11
1For cable types not listed, please contact JMA Technical Support.

07/18/23