UXP-DF-114

7-16 DIN Female Connector for 1 1/4” Cable

General Specification
Interface/gender 7-16 DIN female
Cables supported1 Manufacturer P/N Manufacturer P/N
RFS UCF114 CommScope AVA6
NK Draka RFA114 AL6
Eupen Flexline 1-1/4"R Rosenberger SL 1-1/4" R
LS/Superior Essex LHF 33D    
Weight 1.056 lb | 479.0 g
JMA Weather Protection System WPS-6 used for in-line connections only
Tools required JMA part number Comment
Cable preparation SP-114 No coring required
Connector compression HCG-FRAMESET-114, HCG-CC  
Hex width 38 mm | 1-1/2 in.  
Frequency band VSWR Return loss (dB)
DC-1000 MHz 1.02 40
1000–2000 MHz 1.03 36
2000–4000 MHz 1.05 32
4000–6000 MHz 1.08 28
Electrical Specification Comment
Connector impedance 50 ohm  
Operating frequency band DC–6 GHz  
3rd order IMD dynamic, (PIM) -161 dBc, typical IEC 62037-2, -3
DC test voltage 4000 V  
Center contact resistance ≤ 0.4 milliohm  
Outer contact continuity 1.5 milliohm max.    
Average power 3000 W @ 900 MHz  
Peak power, max. 40 kW  
Insertion loss, typical 0.05 dB Per connector
Shielding effectiveness < -130 dB @ 0-1 GHz
Mechanical Specification Comment
Pull force combined 1.89 kN | > 425 lb Cable limited
Cable retention torque 54.2 N·m | 40 lbf·ft Cable limited
Interface durability 50 cycles IEC 61169-4:9.5
Environmental Specification Test
Operating temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Storage temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Accelerated UV 1000 hr ASTM G154
Immersion test method Mated & unmated, IP68 IEC 60529:2001 & ANSI/SCTE 60
Water jetting test method Mated & unmated, IP66 IEC 60529:2001
Mechanical shock test method Pass IEC 60068-2-27
Thermal shock test method Pass IEC 60068-2-14
Vibration test method 100 m/s2, 2 Hz to 200 Hz IEC 61169-1:2003
Corrosion test method 1000 hr IEC 60068-2-11
1For cable types not listed, please contact JMA Technical Support.

11/28/23