UPL-NM-12S

N Male Connector for 1/2" Superflexible Plenum Cable

General Specification
Interface/gender N Male
Cables supported1 Manufacturer P/N Manufacturer P/N
CommScope HS4RP Superior Essex H FSC12DPV
Wireless Supply WS12/SF/WP    
Weight 125.6 g | 0.277 lb
JMA Weather Protection System N/A
Tools required JMA part number Comment
Cable preparation SP-12SPL No coring required
Connector compression HCG-FRAMESET-1/2, HCG-CC Insert B
Torque wrench TW1412 1.58 N·m | 14 lbf·in
Frequency band VSWR Return loss (dB)
555–1000 MHz 1.02 40
1000–2700 MHz 1.03 36
2700–3800 MHz 1.05 32
3800–6000 MHz 1.08 28
Electrical Specification Comment
Connector impedance 50 ohm  
Operating frequency band DC–6 GHz  
3rd order IMD dynamic, (PIM) -161 dBc, typical IEC 62037-2
DC test voltage 2000 V  
Center contact resistance ≤ 1.5 milliohm  
Outer contact continuity 0.3 milliohm max.  
Average power 600 W @ 900 MHz  
Peak power, max. 10 kW  
Insertion loss, typical 0.05 dB Per connector
Shielding effectiveness < -120 dB @ 0-1 GHz
Mechanical Specification Comment
Pull force combined .78 kN | >175 lb Cable limited
Cable retention torque 6.7 N·m | 5 lbf·ft Cable limited
Interface durability 500 cycles IEC 61169-4:9.5
Environmental Specification Test
Operating temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Storage temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Accelerated UV 1000 hr ASTM G154
Immersion test method Mated & unmated, IP68 IEC 60529:2001 & ANSI/SCTE 60
Water jetting test method Mated & unmated, IP66 IEC 60529:2001
Mechanical shock test method Pass IEC 60068-2-27
Thermal shock test method Pass IEC 60068-2-14
Vibration test method 100 m/s2, 2 Hz to 200 Hz IEC 61169-1:2003
Corrosion test method 1000 hr IEC 60068-2-11
1For cable types not listed, please contact JMA Technical Support.

11/06/24