General | Specification | |||||
---|---|---|---|---|---|---|
Interface/gender | 7-16 Female | |||||
Cables supported1 | Manufacturer | P/N | Manufacturer | P/N | Manufacturer | P/N |
JMA Wireless | JMA12P-50 | RFS | ICA12-50JPL | Wireless Supply | 12/WP | |
CommScope | HL4RPV-50 | ICA12-50JPLB | Rosenberger | RLCX-SL012R | ||
HL4RPV-50B | ICA12-50JPLR | Eupen | EC4-50PL | |||
HL4RPV-50R | ICA12-50JPLW | Belden | RA500P | |||
AL4RPV-50 | ICA12-50JPLLR | Acome | HPL 50-1/2F | |||
HUBER+SUHNER | Sucofeed_1/2_PW | ICA12-50JPLLW | HPL 50-1/2F ALU | |||
LS/Superior Essex | LHF12DPV | |||||
Weight | 140.2 g | 0.309 lb | |||||
JMA Weather Protection System | N/A |
Tools required | JMA part number | Comment |
---|---|---|
Cable preparation | SP-12PL-01 | Bit “V1” all cables |
Connector compression | HCG-FRAMESET-1/2, HCG-CC | Insert D |
Hex width | 32 mm | 1-1/4 in. |
Frequency band | VSWR | Return loss (dB) |
---|---|---|
555–1000 MHz | 1.02 | 40 |
1000–2700 MHz | 1.03 | 36 |
2700–3800 MHz | 1.05 | 32 |
3800–6000 MHz | 1.08 | 28 |
Electrical | Specification | Comment |
---|---|---|
Connector impedance | 50 ohm | |
Operating frequency band | DC–6 GHz | |
3rd order IMD dynamic, (PIM) | -161 dBc, typical | IEC 62037-2 |
DC test voltage | 4000 V | |
Center contact resistance | ≤ 0.8 milliohm | |
Outer contact continuity | 1.5 milliohm max. | |
Average power | 1100 W @ 900 MHz | |
Peak power, max. | 40 kW | |
Insertion loss, typical | 0.05 dB | Per connector |
Shielding effectiveness | < -120 dB | @ 0-1 GHz |
Mechanical | Specification | Comment |
---|---|---|
Pull force combined | .89 kN | > 200 lb | Cable limited |
Cable retention torque | 6.7 N·m | 5 lbf·ft | Cable limited |
Interface durability | 50 cycles | IEC 61169-4:9.5 |
Environmental | Specification | Test |
---|---|---|
Operating temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
Storage temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
Accelerated UV | 1000 hr | ASTM G154 |
Immersion test method | Mated & unmated, IP68 | IEC 60529:2001 & ANSI/SCTE 60 |
Water jetting test method | Mated & unmated, IP66 | IEC 60529:2001 |
Mechanical shock test method | Pass | IEC 60068-2-27 |
Thermal shock test method | Pass | IEC 60068-2-14 |
Vibration test method | 100 m/s2, 2 Hz to 200 Hz | IEC 61169-1:2003 |
Corrosion test method | 1000 hr | IEC 60068-2-11 |
|
©2024 JMA Wireless. All rights reserved. This document contains proprietary information. All products, company names, brands, and logos are trademarks™ or registered® trademarks of their respective holders. All specifications are subject to change without notice. +1 315.431.7100 customerservice@jmawireless.com |